Industrial Valves - Proportional; directional valve; size D08 NG25; 2-stage
Code du modèle : KDG5V-8-33C330N200-M-U-H1-20
Modifier la configuration
Modifier la configuration
Outils et ressources
Spécifications du produit
Fonction | Code | Description |
---|---|---|
TYPE DE VALVE | K | (K) VALVE PROPORTIONNELLE |
TYPE DE CONTRÔLE | D | (D) VALVE DE DISTRIBUTION (DOUBLE SOLÉNOÏDE) |
FIXATION | G | (G) MONTAGE SUR EMBASE |
FONCTIONNEMENT | 5 | (5) COMMANDE PAR SOLÉNOÏDE, ACTION PILOTÉE |
VALEUR DE PRESSION NOMINALE | V | (V) PRESSION MAX. 350 BAR POUR 5,7,8 ET 250 BAR POUR 10 SUR P, A ET B |
INTERFACE | -8 | (8) ISO-4401-AE-08-4-A |
TYPE DE TIROIR | -33 | (33) P FERMÉ, PURGE A ET B VERS T |
DISPOSITIF À RESSORT | C | (C) DOUBLE SOLÉNOÏDE KDG4V UNIQUEMENT |
DÉBIT NOMINAL | 330N200 | (330N200) PORT A 330 L/MIN (87,4 GALLONS US/MIN) ET PORT B 200 L/MIN (52,8 GALLONS US/MIN) |
ALIMENTATION PILOTE | _ | (0) PRESSION PILOTE INTERNE SANS RÉDUCTEUR DE PRESSION |
DRAIN PILOTE | _ | (0) DRAIN PILOTE EXTERNE |
COMMANDE MANUELLE | _ | (0) COMMANDE MANUELLE |
IDENTIFICATION DU SOLÉNOÏDE | -M | (M) DRAPEAU AVEC CONSTRUCTION STANDARD CONFORMÉMENT À ANSI B93 9 |
CONNEXION ÉLECTRIQUE | -U | (U) CONNECTEUR ISO 4400, DIN 43650 |
TENSION DE BOBINE | -H | (H) 24 V CC |
PRESSION SUR PORT DU RESERVOIR | 1 | (1) 8 BAR MAXIMUM |
CODE DE CONSTRUCTION | -20 | (20) SÉRIE DE L'INTERFACE 8 |
FONCTIONNALITÉS SPÉCIALES | _ | AUCUN(E) |