Vickers
02-323194
02-323194
Industrial Valves - Proportional; directional valve; size D07 NG16; 2-stage
Code du modèle : KDG5V-7-33C170N-X-M-U-H1-10
Modifier la configuration
Modifier la configuration
Outils et ressources
Spécifications du produit
Fonction | Code | Description |
---|---|---|
TYPE DE VALVE | K | (K) VALVE PROPORTIONNELLE |
TYPE DE CONTRÔLE | D | (D) VALVE DE DISTRIBUTION (DOUBLE SOLÉNOÏDE) |
FIXATION | G | (G) MONTAGE SUR EMBASE |
FONCTIONNEMENT | 5 | (5) COMMANDE PAR SOLÉNOÏDE, ACTION PILOTÉE |
VALEUR DE PRESSION NOMINALE | V | (V) PRESSION MAX. 350 BAR POUR 5,7,8 ET 250 BAR POUR 10 SUR P, A ET B |
INTERFACE | -7 | (7) ISO-4401-AD-07-4-A |
TYPE DE TIROIR | -33 | (33) P FERMÉ, PURGE A ET B VERS T |
DISPOSITIF À RESSORT | C | (C) DOUBLE SOLÉNOÏDE KDG4V UNIQUEMENT |
DÉBIT NOMINAL | 170N | (170N) 170 L/MIN (45 GALLONS US/MIN) AVEC RÉGLAGE DU DÉBIT D’ENTRÉE ET DE SORTIE |
ALIMENTATION PILOTE | -X | (X) PRESSION PILOTE INTERNE AVEC RÉDUCTEUR DE PRESSION |
DRAIN PILOTE | _ | (0) DRAIN PILOTE EXTERNE |
COMMANDE MANUELLE | _ | (0) COMMANDE MANUELLE |
IDENTIFICATION DU SOLÉNOÏDE | -M | (M) DRAPEAU AVEC CONSTRUCTION STANDARD CONFORMÉMENT À ANSI B93 9 |
CONNEXION ÉLECTRIQUE | -U | (U) CONNECTEUR ISO 4400, DIN 43650 |
TENSION DE BOBINE | -H | (H) 24 V CC |
PRESSION SUR PORT DU RESERVOIR | 1 | (1) 8 BAR MAXIMUM |
CODE DE CONSTRUCTION | -10 | (10) SÉRIE D'INTERFACES 5 ET 7 |
FONCTIONNALITÉS SPÉCIALES | _ | AUCUN(E) |